Trace native Windows clock RPC failure without changing trust checks
This commit is contained in:
@@ -259,6 +259,87 @@ pub fn named_pipe_diagnostic() -> ClockReport {
|
||||
}
|
||||
.report()
|
||||
}
|
||||
/// Diagnostic-only ABI captured before the existing C layout guard. Presence
|
||||
/// flags are numeric0/1; no remote pointers, names or returned entries escape.
|
||||
#[derive(Clone, Copy, Debug, Default, Serialize)]
|
||||
#[repr(C)]
|
||||
pub struct StatusRpcTrace {
|
||||
pub stage: u32,
|
||||
pub native_rpc_return: u32,
|
||||
pub native_rpc_return_present: u32,
|
||||
pub rpc_exception: u32,
|
||||
pub status_present: u32,
|
||||
pub ul_size: u32,
|
||||
pub c_entries: u32,
|
||||
pub p_entries_present: u32,
|
||||
}
|
||||
#[derive(Debug, Serialize)]
|
||||
pub struct StatusRpcDiagnostic {
|
||||
pub rpc_code: u32,
|
||||
pub independent_call: bool,
|
||||
pub trace: Option<StatusRpcTrace>,
|
||||
pub diagnostic_only: bool,
|
||||
pub adapter_qualified: bool,
|
||||
pub trusted: bool,
|
||||
}
|
||||
/// The fixed authenticated named-pipe call is observed separately. It never
|
||||
/// selects a production transport or supplies a trusted timestamp. One worker,
|
||||
/// one outstanding call and no replacement/retry after a local timeout.
|
||||
pub fn status_rpc_diagnostic() -> StatusRpcDiagnostic {
|
||||
#[cfg(windows)]
|
||||
let (rpc_code, trace) = {
|
||||
type Reply = std::sync::mpsc::SyncSender<(u32, StatusRpcTrace)>;
|
||||
type Requests = std::sync::mpsc::SyncSender<Reply>;
|
||||
static WORKER: std::sync::OnceLock<Mutex<Option<Requests>>> = std::sync::OnceLock::new();
|
||||
let worker = WORKER.get_or_init(|| {
|
||||
let (sender, receiver) = std::sync::mpsc::sync_channel::<Reply>(1);
|
||||
let created = std::thread::Builder::new()
|
||||
.name("rmm-clock-status-diag".into())
|
||||
.spawn(move || {
|
||||
#[link(name = "rmm_clock_rpc", kind = "static")]
|
||||
#[link(name = "rpcrt4")]
|
||||
#[link(name = "advapi32")]
|
||||
unsafe extern "C" {
|
||||
fn rmm_clock_query_trace(trace: *mut StatusRpcTrace) -> u32;
|
||||
}
|
||||
while let Ok(reply) = receiver.recv() {
|
||||
let mut trace = StatusRpcTrace::default();
|
||||
// SAFETY: fixed8*u32 C ABI; SEH stays contained inside C.
|
||||
let code = unsafe { rmm_clock_query_trace(&mut trace) };
|
||||
let _ = reply.send((code, trace));
|
||||
}
|
||||
})
|
||||
.is_ok();
|
||||
Mutex::new(created.then_some(sender))
|
||||
});
|
||||
if let Ok(mut worker) = worker.try_lock() {
|
||||
let (reply, receiver) = std::sync::mpsc::sync_channel(1);
|
||||
let sent = worker
|
||||
.as_ref()
|
||||
.is_some_and(|sender| sender.try_send(reply).is_ok());
|
||||
if sent
|
||||
&& let Ok((code, trace)) = receiver.recv_timeout(std::time::Duration::from_secs(2))
|
||||
{
|
||||
(code, Some(trace))
|
||||
} else {
|
||||
*worker = None;
|
||||
(1818, None)
|
||||
}
|
||||
} else {
|
||||
(170, None)
|
||||
}
|
||||
};
|
||||
#[cfg(not(windows))]
|
||||
let (rpc_code, trace) = (50, None);
|
||||
StatusRpcDiagnostic {
|
||||
rpc_code,
|
||||
independent_call: true,
|
||||
trace,
|
||||
diagnostic_only: true,
|
||||
adapter_qualified: false,
|
||||
trusted: false,
|
||||
}
|
||||
}
|
||||
/// Read-only negative controls for the separate native readiness program.
|
||||
/// Neither control can produce clock authority, even if the OS accepts it.
|
||||
/// Rejection without a successful genuine status query is not identity proof.
|
||||
@@ -443,6 +524,7 @@ mod tests {
|
||||
}
|
||||
#[test]
|
||||
fn production_clock_stays_closed_until_native_adapter_qualification() {
|
||||
assert_eq!(std::mem::size_of::<StatusRpcTrace>(), 32);
|
||||
assert_eq!(
|
||||
NativeClock::new().now().unwrap_err().to_string(),
|
||||
"CLOCK_ADAPTER_UNQUALIFIED"
|
||||
|
||||
Reference in New Issue
Block a user